During a job, the AutoBoom™ Status Indicator will be displayed on the Envizio
Pro Guidance screen.
This area may display the following indicators for the current status of the
AutoBoom™ system:
Status of the center rack is only displayed if a Glide Series AutoBoom system
capable of controlling the center section is connected to the Envizio Pro console.
Touch the displayed status icon to access the Glide Series AutoBoom™
Calibration screen.
Troubleshooting
The following are a few general tips for troubleshooting the Envizio Pro system.
Refer to the Envizio Pro Installation & Operation manual for detailed
troubleshooting information.
Issue Possible Cause Solution
CANbus cannot
read the Product
Node
CANbus ends
not terminated
Make sure that both ends of the CANbus
system are properly terminated. Refer to
the Envizio Pro Installation & Operation
manual for more information.
Corroded pins
in CANbus
connections
Check CANbus cable connectors for any
highly corroded pins.
Ensure dielectric grease has been
applied to all cable connections exposed
to weather and field conditions.
Moisture in
connection
Check CANbus cable connectors for any
corroded pins.
Ensure dielectric grease has been
applied to all cable connections exposed
to weather and field conditions.
Connectors
not seated
properly
Check that all CANbus cable connectors
are inserted fully (until the locking tab is
engaged).
Be sure to remove any moisture in
connections which were not properly
seated. Check for corroded pins and
apply dielectric grease when
reconnecting CANbus cables.